Residual current circuit breaker (RCCB) Doepke

Add to selection
General information
Ordercode YESSS
09168905
Product code
09168905
EAN code
4014712091405
Product group
Residual current circuit breaker (RCCB)
Brand
Doepke
RCCB 4p, 100A, 1A, Type A, selective, N left RCCB 4p, 100A, 1A, Type A, selective, N left
Product description

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 4 are two-terminal or two-terminal pair residual current circuit-breakers for single- or three-phase networks. In the standard design, the compact devices are just four module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Selective residual current circuit-breakers are used in systems with stacked distribution boards. In case of a fault, the switch in whose system section the residual current is detected switches off. The selective RCCBs provide fire and fault protection (due to indirect contact), but no additional protection (direct contract, personnel protection). Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V, 400 V and a rated frequency of 50 Hz. Properties: response delay for selective design; high immunity against surge currents and mains-voltage-operated secondary current impulses; tripping not dependent on mains and auxiliary voltage; sensitive to AC residual currents and pulsating DC residual currents (type A) compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on", "off" and "tripped"; Neutral conductor position left; Mounting: quick fastening to mounting rail; any installation position; supply from any direction; Application areas: Main distribution boards in extended power supplies with TN-S, TT and TN-C-S systems, such as campsites, marinas, allotment gardens and showrooms. Selective residual current circuit-breakers in most cases protect the cables from the main distribution board to the sub-distribution boards; Excluded is the application in TN-C systems and for the protection of installations in which electronic equipment could generate smooth DC currents or residual currents with frequencies other than 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (Type B or B+); Hints: To ensure the selectivity of the RCCB. the rated residual current of the selective RCCB must be set at least one level higher than the downstream instantaneous switch.

Product specifications
Number of poles
4
Rated current
100 A
Rated fault current
1 A
Leakage current type
A
Rated voltage
400 V
Rated impulse withstand voltage Uimp
4 kV
Width in number of modular spacings
4
Selective protection
Yes
Short-circuit breaking capacity (Icw)
10 kA
Built-in depth
69 mm
Additional equipment possible
Yes
Mounting method
DIN rail
With interlocking device
Yes
Frequency
50 Hz
Surge current capacity
5 kA
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 40 °C
Short-time delayed tripping
No
Pollution degree
2
Connectable conductor cross section multi-wired
1.5 - 50 mm²
Connectable conductor cross section solid-core
1.5 - 50 mm²
Voltage type
AC
Explosion-proof
No
Power loss
22.5 W
RAL-number (similar)
7035
more specifications
^