Earth leakage circuit breaker Doepke

Add to selection
General information
Ordercode YESSS
09174783
Product code
09174783
EAN code
4014712153653
Product group
Earth leakage circuit breaker
Brand
Doepke
Circuit-breaker with RCCB 4-pole, 125A, 0.03A, Type B NK Circuit-breaker with RCCB 4-pole, 125A, 0.03A, Type B NK
Product description

Circuit-breakers with residual current trip (CBR) switch high currents, protect equipment, cables and lines against overcurrent and protect people against electric shock. DFL 8 are compact devices with integrated auxiliary switch and terminals for large conductor cross-sections. Type B switches are AC-DC sensitive at frequencies of 0 Hz (smooth residual currents) to 150 kHz. They have increased resistance to surge currents and lightning. Switches with the characteristic curve NK provide classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimised for facilities at risk of fire. Switches of this variant have a fixed residual response current of 30 mA for the protection of persons. They therefore provide fault and fire protection as well as additional protection (personal protection, protection in the event of direct contact). Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V, 400 V and a rated frequency of 50 Hz. Properties: fixed rated residual current of 0.03 A; rated currents from 100 A to 250 A; rated voltage 230 V, 400 V AC; four-pole; detection of smooth DC residual currents and AC and pulsating DC residual currents; high tolerance against fluctuations in the auxiliary voltage for the detection of type B residual currents; trips independent of mains and auxiliary voltage in the event of type A residual currents and overcurrent; high short-circuit switching capacity; terminals up to 185 mm2; high surge current strength, i.e. low tendency to faulty trips due to transient residual currents; thresholds adjustable for instantaneous and slow-blow overcurrent trip; integrated auxiliary switches; Mounting: mounting on mounting plate; any installation position; supply from below; Application areas: power supplies to purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks with high short-circuit power; In IT networks, the residual current trip of the CBR can be set to switch off in the event of a second earth fault; Thanks to its AC/DC sensitive residual current trip. this AC/DC sensitive CBR is especially suitable for protecting systems with electronic equipment that is not galvanically isolated from the mains at its inputs; use for residual current protection in TN-C networks is excluded.

Product specifications
Release characteristic
Other
Rated current
125 A
Rated fault current
0.03 A
Rated insulation voltage Ui
1000 V
Rated impulse withstand voltage Uimp
4 kV
Width in number of modular spacings
0
Rated voltage
400 V
Number of poles (total)
4
Number of protected poles
3
Leakage current type
B
Frequency
50 Hz
Disconnection characteristic
Short-time delayed
Rated short-circuit breaking capacity according to IEC 60947-2
85 kA
Concurrently switching neutral conductor
Yes
Over voltage category
3
Surge current capacity
5 kA
With interlocking device
Yes
Pollution degree
3
Voltage type
AC
Built-in depth
149 mm
Anti-nuisance tripping version
No
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 70 °C
Connectable conductor cross section solid-core
4 - 16 mm²
Connectable conductor cross section multi-wired
25 - 185 mm²
Power loss
70.6 W
more specifications
^