Frequency converter =< 1 kV Eaton

Add to selection
General information
Ordercode YESSS
3976-9309
Product code
176972
EAN code
04015081714155
Product group
Frequency converter =< 1 kV
Brand
Eaton
Variable frequency drive, 500 V AC, 3-phase, 105 A, 75 Variable frequency drive, 500 V AC, 3-phase, 105 A, 75 kW, IP55/NEMA 1
Product description

Variable frequency drive, Part group reference (e.g. DIL): DA1, Rated operational voltage: Ue = 500 V AC, 3-phase, 600 V AC, 3-phase, Output voltage with Ve: U2 = 500 V AC, 3-phase, 600 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 105 A, Note: Rated operational current at an operating frequency of 4 kHz and an ambient air temperature of +40 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz , Overload cycle for 60 s every 600 s, at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 75 kW, 150 % Overload: IM = 105 A, Assigned motor rating Note: at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 75 kW, 150 % Overload: IM = 102 A, Assigned motor rating Note: at 550 - 600 V, 60 Hz, Assigned motor rating 150 % Overload: P = 100 HP, Assigned motor rating 150 % Overload: IM = 99 A, Degree of Protection: IP55/NEMA 12, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP, EtherCAT, SmartWire-DT, Fitted with: Brake chopper , OLED display, Additional PCB protection, DC link choke, Frame size: FS6, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Product specifications
Mains voltage
500 - 600 V
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
500 Hz
Max. output voltage
600 V
Nominal output current I2N
105 A
Max. output at quadratic load at rated output voltage
75 kW
Max. output at linear load at rated output voltage
75 kW
With control element
Yes
Number of analogue outputs
2
Application in industrial area permitted
Yes
Number of analogue inputs
2
Application in domestic- and commercial area permitted
Yes
Number of digital outputs
2
Supporting protocol for TCP/IP
Yes
Number of digital inputs
5
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP55
Height
865 mm
Width
330 mm
Depth
313.5 mm
Relative symmetric net frequency tolerance
10 %
Relative symmetric net voltage tolerance
10 %
Degree of protection (NEMA)
12
Power consumption
2250 W
more specifications
^